Fire Doors

We Are Available For You

Fire Doors Doors

These specialist doors are tested against the elements and purpose-built to withstand roaring fires for as long as possible. They enable buildings to compartmentalise and delay the spread of fire from one area to another.

Fire doors have a few vital safety features and really can be the difference between life and death. Two of the most important functions fire doors have are:

  • When closed, they form a barrier to stop the spread of fire
  • When opened, they provide a means of escape

Because of their importance in protecting lives, it is imperative that fire doors receive regular inspections – frequency is likely to depend on many factors, including the age and condition of the door. Fire doors should always be fitted correctly by a competent installer, as they’re a carefully engineered fire safety device.

Under the Regulatory Reform (Fire Safety) Order 2005 (FSO), landlords have a responsibility to ensure their properties and tenants are safe. The ‘responsible person’ has a legal responsibility under the FSO and can be criminally prosecuted if they do not fulfill their duties. The responsibility extends to the requirement for a fire risk assessment in all non-domestic buildings, including the common parts of flats or houses with multiple occupation.

Features of fire doors

Here are some of the key features to look out for in terms of both domestic and commercial use:

  • Fire doors are made up of various components. The door itself is usually made from a       solid timber frame, but they can sometimes be covered again in fire-resistant glass. This       glass should be able to withstand exposure to the heat condition in a fire test for at least 60 minutes before it reaches a temperature high enough to soften it.
  • Around the edges of the door will be the intumescent seal, which is designed to expand when temperatures reach beyond 200°C to seal the gaps between the       door and frame.
  • For a private premises, it is advised to install fire doors where the risk is most imminent, for example the kitchen, or rooms which house lots of electrical devices.       If your property is a new build, it should have been subject to regulations ensuring certain doors are fire doors – check this with the developer. As it currently      stands, fire doors are only legally required in Houses in Multiple Occupation
  • For commercial or non-domestic properties, liability lies with whoever is deemed the ‘responsible person’ for that property or the employer. For example, the      owner of the property, or the person in control of the property for trade reasons would be responsible.
  • Thorough risk assessments must be carried out and it is advisable to get professional help with all fire-safety-related regulations. There is more to passive fire       protection and fire safety than just fire doors; escape routes, lighting, warning systems and equipment checks are also required.
  • Many deaths during fires are not from direct contact with the flames, but the consumption of smoke. With this in mind, keep an eye out for a doorset with cold       smoke seals. These should be within the intumescent seal. Exceptions may apply where the leakage of the smoke is essential for detecting a fire early.

Frequently Asked Questions

Common questions answered by our technical team.

Rudhar Group supplies access control systems using fingerprint recognition (most common, reliable and cost-effective), face recognition (touchless, hygienic), iris recognition (highest accuracy for high-security zones), and palm vein recognition (contactless, very hygienic for food and pharma facilities). Non-biometric options include RFID cards and PIN keypads.

In 1:1 verification, the user presents a card or enters a PIN, and the system verifies their biometric matches the template on record for that specific identity. In 1:N identification, the user only presents their biometric and the system compares it against the entire enrolled database to find a match.

Yes. Rudhar Group biometric systems are supplied with management software that records all entry-exit events with timestamp and user identity. This data can be used for attendance management, overtime calculation and shift reporting. Integration with popular HR and payroll systems is available.

Access control systems from Rudhar Group include fail-safe and fail-secure options. A battery backup (typically 4-8 hours) maintains system operation during power cuts. Local memory in each reader stores up to 10,000-100,000 events offline when network connectivity is interrupted.

Entry-level biometric readers support 1,000-3,000 enrolled users. Mid-range enterprise systems support 10,000-50,000 users. Large-scale systems for industrial campuses can accommodate 100,000+ users with server-based management.

Rudhar Group standard biometric systems store biometric templates locally on the reader hardware or on an on-premises server, not in the cloud. Biometric templates are stored as mathematical feature vectors that cannot be reverse-engineered. Cloud-connected systems use AES-256 standard encryption complying with India Personal Data Protection norms.
Get a Quote